#Siemens simatic pdm software update

A CVSS v3 base score of 7.3 has been calculated the CVSS vector string is ( AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:L). End Update A Part 1 of 2 - 4.2 VULNERABILITY OVERVIEW 4.2.1 INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732Īn attacker could change the content of certain metafiles and subsequently manipulate parameters or the behavior of devices that would be later configured by the affected software.ĬVE-2021-31894 has been assigned to this vulnerability. SINAMICS STARTER (containing STEP 7 OEM version): All versions prior to 5.4 SP2 HF1.SIMATIC STEP 7 V5.X: All versions prior to v5.7.SIMATIC PCS 7 V8.2 and earlier: All versions.

#Siemens simatic pdm software software
Siemens reports this vulnerability affects the following SIMATIC software products: Successful exploitation of this vulnerability could allow an attacker to manipulate parameters or the behavior of devices configured by the affected software products. This updated advisory is a follow-up to the original advisory titled ICSA-21-194-06 Siemens SIMATIC Software Products that was published July 13, 2021, to the ICS webpage on.
#Siemens simatic pdm software serial
I couldn’t do anything more for the customer over the phone, so I grabbed my serial comms toolkit and headed to the site myself. Plus, they’d used the serial port successfully for other connections. The customer’s IT guy ran a port scan program, but could find on application or service running on COM1. Siemens tech support had offered the customer several “Try This/Try That” suggestions, but came to the conclusion that a software program on the customers’ laptop had locked up the laptop’s internal serial port so PDM couldn’t access it. The salesman had lent the customer his “known good” serial cable that he’d used for the successful upload.
#Siemens simatic pdm software windows
He had a Siemens MultiRanger 100 ultrasonic level transceiver, and was trying to connect to it via Modbus using Siemens SIMATIC PDM software on his Windows XP laptop PC.Įarly on, the Lesman salesman who worked with this customer had connected to the MultiRanger from his laptop using PDM, but only one upload worked successfully. The goof happened at a customer site last week. (Rule #1: Test EVERYTHING!) That one oversight cost me three hours when I could have solved a problem in three minutes. Sometimes I get lazy and don’t follow my own rules.